- You cannot add "Anritsu MP1800A Signal Analyzer with Options 001, 002 and 015" to the cart because the product is out of stock.
Used
The Agilent Keysight E4448A PSA gives unparalleled levels of measurement capability up to 50 GHz.
Includes Options: 115/215/AYZ
Dynamic Range
-154 dBm displayed average noise level (DANL)
+17 dBm third order intercept (TOI) (+19 dBm typical)
-114 dBc/Hz phase noise at 10 kHz offset
Speed
Fast low-level spur search
50 measurements per second local update rate (45 for remote operation)
Agilent E4448A Standard Features
All-digital IF with auto-ranging capability
Phase noise optimization
Full detector suite
160 resolution bandwidth settings (10% steps)
2 dB step attenuator
FFT and swept measurement modes
Power Suite one-button power measurements
*Photo and serial number may be a like representation, for more detailed information please contact us prior to ordering.
Read MoreThe E4440A PSA spectrum analyzer measures and monitors complex microwave and RF signals ranging between 3Hz and 26.5GHz. The Keysight external mixer and third-party mixers can expand the frequency coverage to 110GHz and 325GHz, respectively.
This high-performance PSA spectrum analyzer has a wide set of features, such as powerful one-button measurements and an outstanding combination of flexibility, speed, accuracy, dynamic range, and analysis bandwidth
Tektronix 80C07B -CR Optical Sampling Module, Multi-rate Datacom/Telecom w/Option CR1- 2.5 GHz Clock/Data Recovery
The 80C07B module is a broad wavelength (700 to 1650 nm) multi-rate optical sampling module optimized for testing datacom/telecom signals from 125 to 2500 Mb/s.
With its amplified O/E converter design, this module provides excellent signal-to-noise performance, allowing users to examine low-power optical signals. The 80C07B can be optionally configured with clock recovery that supports 125, 155, 622, 1063, 1250, 2125, 2488, 2500 and 2666 Mb/s rates.
Read MoreThe Tektronix DPO7254 is part of Tektronix’s new generation of real-time digital phosphor oscilloscopes and are the industry’s best solution to the challenging signal integrity issues faced by designers verifying, characterizing, debugging and testing sophisticated electronic designs.
Unit includes:
DDRA – DDR Memory Technology Analysis Package
DJA – Jitter and Eye-Diagram Analysis – Advanced
Read MoreKeysight E4443A-111/115/1DS/219/226/241 PSA Series Spectrum Analyzer, 3 Hz – 6.7 GHz
The HP/Agilent E4443A PSA high-performance spectrum analyzer measures and monitors complex RF signals up to 6.7 GHz. Agilent E4443A Key Specifications Dynamic Range -155 dBm displayed average noise level (DANL) +17 dBm third order intercept (TOI) (+19 dBm typical) -116 dBc/Hz phase noise at 10 kHz offset (-118 dBc/Hz typical) Accuracy ±0.62 dB absolute amplitude accuracy (±0.24 dB typical) ±0.38 dB frequency response (±0.11 dB typical) ±0.07 dB log amplification linearity Speed Fast low-level spur search < 30 ms fast ACP measurement 50 measurements per second local update rate (45 for remote operation)
Read MoreThe Anritsu mmW modules are compact, low-profile, and lightweight which facilitates mounting on the micropositioners associated with semi-automatic or manual probe stations. The 3740A Transmission/Reflection modules have simultaneous transmission and reflection capability. A pair of 3740A modules allows measurement of all four S-parameters of a two-port device.
Anritsu 3740A-V Millimeter Wave Module, V-Band (WR-15), 50 to 75 GHz
Read MoreAnritsu 3738A Broadband Test Set
The Anritsu 3738A broadband test set is an instrument which measures the complex transmission and reflection characteristics of two-port devices in the frequency domain. It does this by sampling the incident signal, separating the transmitted and reflected waves, and then performing ratios that are directly related to the reflection and transmission coefficients of the two-port. Frequency is swept to rapidly obtain amplitude and phase information over a band of frequencies of interest.
Anritsu 3738A utilize synthesized-frequency sources to provide a known test stimulus that can sweep across a range of frequencies or power levels. Anritsu 3738A network analyzers also can perform ratioed measurements (including phase), which require multiple receivers. The Anritsu 3738A can provide a wealth of knowledge about a device under test (DUT), including its magnitude, phase, and group-delay response.
Read MoreKeysight 3458A Digital Multimeter, 8.5 Digit
The Agilent Keysight 3458A Multimeter shatters long-standing performance barriers of speed and accuracy on the production test floor, in R&D, and in the calibration lab. The Agilent 3458A is simply the fastest, most flexible, and most accurate multimeter ever offered by Agilent Technologies. In your system or on the bench, the Agilent 3458A saves you time and money with unprecedented test system throughput and accuracy, seven function measurement flexibility, and low cost of ownership.
Select a reading rate of 100,000 readings per second for maximal test throughput. Or achieve highest levels of precision with up to 8.5 digits of measurement resolution and 0.1 part per million transfer accuracy. Add this to the Agilent 3458A’s simplicity of operation, and you have the ideal multimeter for your most demanding applications.
Read MoreThe ROHDE – SCHWARZ FSEM20 Spectrum Analyzer is a advanced, high speed, high performance analyzer tailored to the requirements of modern digital communication systems.
The FSEM20 can also be used as a general purpose analyzer, it’s 9 kHz to 26.5 GHz bandwidth and excellent technical features make it a versatile analyzer for many applications.
– 24-cm LCD 9.5″ display
– More than 20 sweeps/s
– 8 Markers
– Frequency counter w/ sel resolution
– Numerous level & Frequency lines
– Split-screen display
– Quasi-analog display
– Minimum Sweep Time 1 us
– Maximum Sweep Time 1500 s
– -Resolution Bandwidth Steps 1/2/3/5
– Minimum Video Bandwidth 1 Hz
– Maximum Video Bandwidth 10 MHz
– Video Bandwidth Steps 1/2/3/5