Used

Home » Used » Page 133

Keysight 1155A Low Mass Active Probe, 750- MHz, 2-Channel

August 10, 2018

The Agilent 1155A is a two-channel low mass active probe for Agilent Infiniium oscilloscopes. It combines a probe tip that weighs less than 1 gram with the superior performance of an active probe. It’s a powerful combination ideal for attaching to fine-pitch ICs and probing surface mount components.

Read More

Keysight 1154A Differential Probe, 500 MHz

August 10, 2018

The Agilent 1154A is a FET input differential probe with 500 MHz bandwidth and greater than 40 dB CMRR (Common Mode Rejection Ratio) at 10 MHz. The 1154A offers the flexibility of 10X gain and 10:1 attenuation for a maximum of 100:1 attenuation.

Read More

Keysight 1153A 200 MHz Differential Probe

August 10, 2018

The Agilent 1153A is a 1:1 FET differential probe with 200 MHz bandwidth and 3000:1 CMRR (Common Mode Rejection Ratio) at 1 MHz. The probe has an input resistance of 1 MO and low input capacitance of 7 pF to minimize circuit loading.

Read More

Keysight 1152A Active Probe, 2.5 GHz

August 10, 2018

The Agilent 1152A active probe’s bandwidth, superior accuracy, and reliability make it an ideal companion for the Agilent 54845A 1.5 GHz bandwidth oscilloscope. The low input capacitance of the active probe eliminates distortion caused by excessive loading. As frequency increases, probe tip capacitance decreases the impedance of the probe by Xc=1/(2pi*fC), resulting in measurement error, depending on the source impedance of the output device. The Agilent 1152A’s low tip capacitance becomes a distinct advantage as frequency increases. Nonintrusive, reliable probing provides faithful reproduction of signals.

Read More

Keysight 1144A Active Probe, 800 MHz

July 10, 2018

The Agilent 1144A active probe provides an excellent combination of high bandwidth, high input resistance, and low input capacitance. This combination is superior to that of passive divider probes because it provides minimal circuit loading at high and low frequencies. As signal speeds increase, passive divider probes may not deliver the performance needed. This can result in waveshapes that do not represent the actual signal. To help you minimize circuit loading, the Agilent 1144A boasts a 800 MHz bandwidth, 1 M Ohm input resistance, and 2 pF input capacitance. It can be connected to any instrument with 50 Ohm inputs. An external 50 Ohm termination can also be used with high impedance inputs. For use with 6000 Series 300 MHz – 1 GHz, 54641A/D and 54642A/D oscilloscopes the Agilent 01144-61604 adapter can be used with this power supply to provide power for two channels of active probing. Versatile accessories allow for easy connection to your device under test. For example, the dual lead adapter combines with the two mini-pincher tips to provide a solid connection to 0.050 inch pitch surface mount devices for hands-off probing. Also, the ground bayonet has a short ground lead to minimize measurement errors such as ringing, caused by parasitic inductances. For hands-off probing of SMT components with 0.5 mm (0.020 inch) to 0.8 mm (0.032 inch) pitch, an additional accessory is available: the Agilent 10075A 0.5 mm IC Clips Accessory Kit.

Read More

Keysight 1142A Probe Control and Power Module

August 10, 2018

The Agilent 1142A Probe Control and Power Module can power and control the 1141A Differential Probe, 1144A 800 MHz Active Probe and the 1145A 750 MHz Active Probe for SMD If the instrument does not have an internal 50-ohm termination, an external termination can be used with high-impedance inputs.

Read More

Keysight 1141A 200 MHz Differential Probe – New

August 10, 2018

The Agilent 1141A is a 1X FET differential probe with 200 MHz bandwidth and 3000:1 CMRR (Common Mode Rejection Ratio) at 1 MHz. The probe has an input resistance of 1 MO and low input capacitance of 7 pF, to minimize circuit loading. The Agilent 1141A 200 MHz Differential Probe must be used with the Agilent 1142A Probe Control and Power Module. It can be connected to any instrument with 50 ohm inputs. An external 50 ohm termination can also be used with high impedance inputs.

Read More

Keysight 1134A InfiniiMax 7 GHz Probe

August 10, 2018

The InfiniiMax 7 GHz 1134A probe amplifier (in conjunction with the E2669A differential or E2668A single-ended connectivity kits), was designed to be used with the Infiniium 6 GHz 54855A oscilloscope. This combination provides a full system bandwidth of 6 GHz to the probe tip. InfiniiMax maximizes measurement performance for both hands-on (e.g., browsing) or hands-off measurements, such as solder-in, socketed or SMA connections.

Read More

Keysight 1132A InfiniiMax Probe, 5 GHz

August 10, 2018

The InfiniiMax 5 GHz 1132A probe amplifier (in conjunction with the E2669A differential or E2668A single-ended connectivity kits), was designed to be used with the Infiniium oscilloscopes. This combination provides a full system bandwidth of 4 GHz to the probe tip. InfiniiMax maximizes measurement performance for both hands-on (e.g., browsing) or hands-off measurements, such as solder-in, socketed or SMA connections.

Read More