equipment
Keysight 8346A Amplifier, Microwave
Agilent HP Keysight 8346A Amplifier, Microwave
Read MoreThis unit has 1 Meg Memory and comes with 3852A Data Acquisition and Control System with 1 Meg Memory and (2) 44705A’s, (1) 44708A and (1) 44725A.
You can easily configure an Agilent 3852A data acquisition and control system to meet your needs for measuring physical parameters. The 3852A is set up to handle many different transducer inputs including thermocouples, thermistors, RTDs, and strain gages, as well as being ready to measure dc volts, currents, resistances, pulse counts, frequencies, and more. The 3852A mainframe has eight (8) slots for plug-in function modules, and has provisions for extending the mainframe (the 3853A) for large systems requiring more plug-in cards.
Choose from three digital voltmeters to meet your measurement needs. The voltmeters can be used in the mainframe or the extenders, and multiple voltmeters are allowed in each mainframe. With the 3852A you can choose from a complete set of input and output plug-in modules that provide a variety of measurement and output-controlling capabilities.
The 3852A has built-in, 68000-based intelligence to increase the speed and effectiveness of the system and to collect, analyze, and respond to data. Control decisions are handled quickly using subroutines running within the mainframe (not having to communicate via GPIB to an external computer in every case). This intelligence can be used to return only the most significant data to the computer, increasing its efficiency with other tasks. The power of this front-end intelligence, in combination with an 9000 Series 300 computer and optional data acquisition software, adapts easily to testing your product or characterizing your processes. Or, if you prefer, you may configure your system to run with a PC as the host computer, possibly incorporating the Graphical Programming Language from Agilent VEE.
Read MoreKeysight 3852A Data Acquisition and Control System with 1 Meg Memory and (2) 44705A’s, 44708A and 44725A
This unit has 1 Meg Memory and comes with 3852A Data Acquisition and Control System with 1 Meg Memory and (2) 44705A’s, (1) 44708A and (1) 44725A.
You can easily configure an Agilent 3852A data acquisition and control system to meet your needs for measuring physical parameters. The 3852A is set up to handle many different transducer inputs including thermocouples, thermistors, RTDs, and strain gages, as well as being ready to measure dc volts, currents, resistances, pulse counts, frequencies, and more. The 3852A mainframe has eight (8) slots for plug-in function modules, and has provisions for extending the mainframe (the 3853A) for large systems requiring more plug-in cards.
Choose from three digital voltmeters to meet your measurement needs. The voltmeters can be used in the mainframe or the extenders, and multiple voltmeters are allowed in each mainframe. With the 3852A you can choose from a complete set of input and output plug-in modules that provide a variety of measurement and output-controlling capabilities.
The 3852A has built-in, 68000-based intelligence to increase the speed and effectiveness of the system and to collect, analyze, and respond to data. Control decisions are handled quickly using subroutines running within the mainframe (not having to communicate via GPIB to an external computer in every case). This intelligence can be used to return only the most significant data to the computer, increasing its efficiency with other tasks. The power of this front-end intelligence, in combination with an 9000 Series 300 computer and optional data acquisition software, adapts easily to testing your product or characterizing your processes. Or, if you prefer, you may configure your system to run with a PC as the host computer, possibly incorporating the Graphical Programming Language from Agilent VEE.
Read MoreKeysight 11729B Phase Noise Carrier with Option 301
HP/Agilent Keysight 11729B Phase Noise Carrier with Option 3015 MHz to 18 GHz
- Phase noise and AM noise measurements
- Low system noise floor
The Hewlett Packard 11729C Carrier Noise Test Set is an integral part of a phase noise measurement system. The HP 11729C can perform the following operations up converts an external (or internal) reference signal, down converts the signal under test to an intermediate frequency (IF). The phase demodulates phase noise of the test signal using the Phase Detector Method; frequency demodulates the phase noise of the test signal using the Frequency Discriminator Method.
HP/Agilent Keysight 11729C Carrier Noise Test Set with Options 130/H33
Read MoreEIP 548A Microwave Frequency Counter with Options 05/06/08
- Frequency range of: 10 Hz-26.5 GHz
- Sensitivity: -20dBm (10 Hz-1 GHz); -30dBm (1 GHz-12.4 GHz); -25 dBm (12.4 GHz-18.0 GHz); -20 dBm (18 GHz-22 GHz); -15 dBm (22 GHz-26.5 GHz)
- Acquisition time: 1 mS for 1 kHz resolution; 1 S for 1 Hz resolution
- Input impedance: 50 ohms
- Resolution: 1 Hz-1 GHz
The Agilent 6050A electronic load mainframe accepts user-installable Agilent load modules for easy system configuration and future reconfiguration. The 6050A holds up to six 60501B, 60502B, and 60503B load modules, or three 60504B and 60507B load modules, allowing up to 1,800 watts of total maximum power. One GPIB address is all you need for complete control and readback of all load modules within a single mainframe.
This unit includes Option 908
Read MoreHughes 8010H Traveling Wave Tube Amplifier 8-18Ghz @ 10 Watts