Used

Home » Used » Page 128

Keysight 85131F Flexible Cable Set, 3.5mm to 3.5mm

August 10, 2018

See Velocity Microwave TPXKIT-35-FM-26.  Repairable – Lower Cost – 2-Year Warranty -10-Year Support

The Agilent 85131F is a 62.2 cm (24.5 in) long flexible cable set composed of a 3.5 mm female to PSC-3.5 mm female connector and a 3.5 mm female 2 to a 3.5 mm male connector. Cable frequency range is dc to 26.5 GHz.

 

Read More

Keysight 85131D Semi-Rigid Cable Set, 3.5mm to 3.5mm

August 10, 2018

The Agilent 85131D is an 53 cm (21 in) long 1 semi-rigid cable set composed of a 3.5 mm female 2 to PSC-3.5 mm female connector and a 3.5 mm female 2 to 3.5 mm male connector. Cable frequency range is dc to 26.5 GHz with a return loss of 16 dB or better. Insertion loss is 0.3 * sqrt(f) + 0.2 dB, where f is frequency in GHz, for the test port connector and 1.8 dB at maximum frequency for the device connector. Phase stability of semi-rigid/flexible cables is specified with a 90 degree bend using a 4 to 3 inch radius. Stability 1 of the Agilent 85131D is less than 0.06 dB and phase is 0.16 * f + 0.5, where f is frequency in GHz. 1 Cable length and stability are supplemental characteristics. 2 Special rugged female connector is designed specifically for connecting to the network analyzer test port, but does not mate with a standard male connector.

Read More

Keysight 85131B Test Port Return Cable Set, 3.5mm, DC-26.5 GHz

August 10, 2018

The 85131B Test Port Return Cable Set is a pair of cables for use with the 8515A S-Parameter Test Set. The device under test is connected between the cables during measurement. The frequency range is dc to 26.5GHz. The cable length is 24″. VSWR is 1.22:1 typical. The cable uses special 3.5 mm and precision 3.5 mm (one male or female) connectors.

Read More

Keysight 85130D Test Port Adapter Set, 3.5mm to 3.5mm

August 10, 2018

The Agilent 85130D test port adapter is designed to protect the test set port when it would be directly connected to the device under test. These adapters have a special rugged female connector designed for connecting to the network analyzer test port. This special connector will not mate with a standard male connector, but converts the rugged test set port to a connection that can be mated with the device under test. The set contains a 3.5 mm to PSC-3.5 mm male adapter and a 3.5 mm to PSC-3.5 mm female adapter. The frequency range for these adapters is dc to 26.5 GHz with a return loss of 28 dB or better.

Read More

Keysight 85130B Test Port Adapter Set, 3.5 mm to 7 mm

August 10, 2018

The Agilent 85130B test port adapter is designed to protect the test set port when it would be directly connected to the device under test. These adapters have a special rugged female connector designed for connecting to the network analyzer test port. This special connector will not mate with a standard male connector, but converts the rugged test set port to a connection that can be mated with the device under test. The set contains two 3.5 mm female to 7 mm adapters. The frequency range for these adapters is dc to 18 GHz with a return loss of 28 dB or better.

Read More

Keysight 85056A Standard Mechanical Calibration Kit, DC to 50 GHz, 2.4mm

July 10, 2018

The Agilent 85056A mechanical calibration kit contains precision standard devices to characterize the systematic errors of Agilent network analyzers in the 2.4 mm interface. This kit also contains adapters to change the sex of the test port, connector gauges for verifying and maintaining the connector interface, and a torque wrench for proper connection. Included are standards definitions on disk.

Read More

Keysight 85037B Precision Detector, 10 MHz to 26.5 GHz – Certiprime

July 25, 2018

The Agilent 85037B precision detector is designed specifically for operation with the 8757D scalar network analyzer and may be used in either ac or dc detection modes. This dual diode detector contains internal frequency correction factors in an internal EE PROM (read automatically by the 8757D) for improved measurement accuracy versus frequency. When used in conjunction with the 8757D’s internal power calibrator (Opt 002), these detectors provide the maximum absolute power measurement accuracy. The 85037B is not compatible with the 8757E, 8757A, 8756A, or 8755.

Read More

Keysight 8493C-006 Coaxial Fixed Attenuator, DC to 26.5 GHz, 6 dB

August 10, 2018

The Agilent 8493C-006 coaxial fixed attenuator provides precision attenuation, flat frequency response, low SWR over broad frequency range. The attenuator has APC-3.5 connectors and nominal attenuation 6 dB. This attenuator is swept-frequency tested to ensure it meets specifications at all frequencies.

Read More

Keysight 8491B-050 Coaxial Fixed Attenuator, DC to 18 GHz, 50 dB

August 10, 2018

Agilent 8491B-050 Coaxial Fixed Attenuator, DC to 18 GHz, 50 dB

Read More